Peptides vs SARMs: How Two Different Compound Classes Compare in Research
Two compound classes that often get bundled together in online discussions: research peptides and SARMs (selective androgen receptor modulators). They get mentioned in the...
The short answer
A COA is only useful if you know what each line proves and what it does not. This guide walks through a typical peptide COA section by section, explains the difference between purity, identity and quantity, and ends with a printable 10-point checklist you can use on any supplier's reports, including ours.
A certificate of analysis records the results of tests run on a specific sample at a specific time. For research peptides, the core tests are usually high-performance liquid chromatography (HPLC) for purity and mass spectrometry (MS) for identity. Some reports also include a quantity result (how many milligrams were actually in the vial), endotoxin or sterility testing.
Three limits are worth keeping in mind:
The report should name the lab that ran the tests, with an address or website you can check. An in-house report from the seller is not the same as an independent result. If the lab name cannot be found anywhere outside the seller's own site, treat the report with caution.
Look for a unique report number (some labs call it a task number) plus the date the sample was received and the date it was tested. These let you match the report to the lab's records and tell you how recent the result is.
The compound name and the batch or lot number should match the label on the vial you have. If a supplier shows one COA for every batch they have ever sold, or the batch field is blank, the report cannot be tied to your vial.
Mass spectrometry measures the mass of the molecules in the sample. The report usually lists an expected (theoretical) mass for the compound and an observed mass. The two should agree closely. Small differences of a fraction of a dalton are normal; large differences suggest the wrong compound, a truncated sequence or a modification.
This matters because HPLC on its own cannot tell you what a peak is. A vial of a different peptide could show a single clean peak at high "purity" and still be the wrong compound. Identity confirmation is what closes that gap. Peptides that differ by only a few residues, such as Semax and Selank, are a good example of why the measured mass should be checked against the label.
HPLC separates the components of a sample as they pass through a column. A detector, usually ultraviolet at around 214–220 nm for peptides, records each component as a peak. Purity is normally reported as the area of the main peak as a percentage of the total peak area.
When reading the purity figure:
Some labs also report how much peptide was found in the vial, for example "10.4 mg" for a vial labelled 10mg. This is separate from purity: a vial can be highly pure but under-filled. Quantity results usually come with a margin of error, so a result a few per cent above or below the label is normal. For concentration maths once you know the real content, our peptide calculator and reconstitution guide show the working.
Endotoxin (often by LAL assay, reported in EU per vial or per mg), sterility, residual solvents and heavy metals are separate tests. They only appear if someone paid for them. If a report does not list them, they were not done; a high HPLC purity says nothing about them.
Many independent labs let anyone confirm a report against their own database. For example, Janoshik Analytical reports carry a task number at the top and a unique key in the footer, which can be entered on the lab's verification page (janoshik.com/verification) to bring up the stored copy. Compare every field on the stored copy with the one you were given: compound, batch, results and dates.
This is the most common point of confusion. Lyophilised peptides are not 100% peptide by weight. Alongside the peptide, the powder contains bound water and counter-ions left over from synthesis and purification, such as trifluoroacetate (TFA) or acetate. These are largely invisible to the UV detector, so they do not lower the HPLC purity figure.
Net peptide content is the share of the total powder weight that is actually peptide. It is measured by other methods, such as amino acid analysis or elemental (nitrogen) analysis, and for many synthetic peptides it is well below 100%. A COA that reports both figures gives a fuller picture. When a report shows only HPLC purity, read it as "how clean is the peptide that is there", not "how much peptide is there". The quantity result in section 6, where offered, is the better guide to content.
Copy or print this list and work through it for each report.
Feel free to share or link to this checklist. If you run a resource page, vendor directory or testing database and would like to reference it, the stable URL is this page.
We publish third-party HPLC results for our core range in the Optic Labs COA library. If anything in a report is unclear, contact us. Our guide to choosing a peptide supplier in Australia covers the other checks worth making, and the peptide storage guide explains how to keep a tested vial in the condition it was tested in.
Browse the full range of research peptides in Australia, including BPC-157, Retatrutide and BAC water.
COA stands for certificate of analysis. It is a laboratory report that records the test results for a specific batch of a product, such as its purity, identity and quantity.
Research-grade peptides are commonly supplied at 98–99% HPLC purity or higher. The figure should come with a chromatogram, and it describes how much of the detectable material is the target peptide, not the total peptide weight in the vial.
HPLC measures purity, meaning how much of the sample is one component. Mass spectrometry measures identity, meaning whether that component has the right molecular mass for the compound on the label. A complete COA reports both.
Net peptide content is lower because lyophilised powder also contains water and counter-ions such as TFA or acetate. These add weight but are not counted by the HPLC detector, so a peptide can be 99% pure by HPLC while the powder is well under 100% peptide by weight.
Enter the task number from the top of the report and the unique key from its footer on Janoshik's verification page, then compare the stored report with your copy field by field. If the codes do not return a match, the report cannot be confirmed.
No. HPLC and mass spectrometry do not test for sterility or endotoxin. Those are separate tests, and a COA only covers them if they are listed in the results.
This article is for educational and research purposes only. Optic Labs products are intended for laboratory research use only and are not for human consumption. Nothing in this article is medical advice or a recommendation to use any compound.