Handling & guides

How to Read a Peptide COA (Certificate of Analysis): A Practical Checklist

8 min read Updated

How to Read a Peptide COA (Certificate of Analysis): A Practical Checklist

The short answer

How do you read a peptide COA? A peptide certificate of analysis (COA) is a lab report for one batch. Read it in this order: check it comes from a named independent lab, that the batch or lot matches your vial, that mass spectrometry confirms the right compound, that HPLC purity is backed by a chromatogram, and that the report can be verified with the lab.
On this page

    A COA is only useful if you know what each line proves and what it does not. This guide walks through a typical peptide COA section by section, explains the difference between purity, identity and quantity, and ends with a printable 10-point checklist you can use on any supplier's reports, including ours.

    What a peptide COA is (and isn't)

    A certificate of analysis records the results of tests run on a specific sample at a specific time. For research peptides, the core tests are usually high-performance liquid chromatography (HPLC) for purity and mass spectrometry (MS) for identity. Some reports also include a quantity result (how many milligrams were actually in the vial), endotoxin or sterility testing.

    Three limits are worth keeping in mind:

    • A COA describes a sample, not a brand. It applies to the batch that was tested. A report from last year's batch says little about this year's.
    • A COA only covers the tests listed. An HPLC purity result does not tell you anything about endotoxin, and a mass result does not tell you about purity.
    • Some fields are supplied by the customer. At most testing labs the sample name, manufacturer and batch number are written on the order by whoever sent the sample in. The lab measures the contents; it does not independently confirm where the vial came from.

    The parts of a peptide COA, line by line

    1. Laboratory name and contact details

    The report should name the lab that ran the tests, with an address or website you can check. An in-house report from the seller is not the same as an independent result. If the lab name cannot be found anywhere outside the seller's own site, treat the report with caution.

    2. Report or task number and dates

    Look for a unique report number (some labs call it a task number) plus the date the sample was received and the date it was tested. These let you match the report to the lab's records and tell you how recent the result is.

    3. Sample name, batch and lot

    The compound name and the batch or lot number should match the label on the vial you have. If a supplier shows one COA for every batch they have ever sold, or the batch field is blank, the report cannot be tied to your vial.

    4. Identity: mass spectrometry

    Mass spectrometry measures the mass of the molecules in the sample. The report usually lists an expected (theoretical) mass for the compound and an observed mass. The two should agree closely. Small differences of a fraction of a dalton are normal; large differences suggest the wrong compound, a truncated sequence or a modification.

    This matters because HPLC on its own cannot tell you what a peak is. A vial of a different peptide could show a single clean peak at high "purity" and still be the wrong compound. Identity confirmation is what closes that gap. Peptides that differ by only a few residues, such as Semax and Selank, are a good example of why the measured mass should be checked against the label.

    5. Purity: HPLC

    HPLC separates the components of a sample as they pass through a column. A detector, usually ultraviolet at around 214–220 nm for peptides, records each component as a peak. Purity is normally reported as the area of the main peak as a percentage of the total peak area.

    When reading the purity figure:

    • Look for the chromatogram. A purity number without the trace it came from is hard to judge. A good chromatogram shows one dominant peak with small, clearly integrated impurity peaks.
    • Read "99%" correctly. HPLC purity means 99% of what the detector can see is the target peptide. It does not mean 99% of the powder's weight is peptide (see net peptide content below).
    • Check the method details if shown. Column type, gradient and wavelength are signs the lab is reporting a real method rather than a template.

    6. Quantity: milligrams per vial

    Some labs also report how much peptide was found in the vial, for example "10.4 mg" for a vial labelled 10mg. This is separate from purity: a vial can be highly pure but under-filled. Quantity results usually come with a margin of error, so a result a few per cent above or below the label is normal. For concentration maths once you know the real content, our peptide calculator and reconstitution guide show the working.

    7. Additional tests

    Endotoxin (often by LAL assay, reported in EU per vial or per mg), sterility, residual solvents and heavy metals are separate tests. They only appear if someone paid for them. If a report does not list them, they were not done; a high HPLC purity says nothing about them.

    8. Verification details

    Many independent labs let anyone confirm a report against their own database. For example, Janoshik Analytical reports carry a task number at the top and a unique key in the footer, which can be entered on the lab's verification page (janoshik.com/verification) to bring up the stored copy. Compare every field on the stored copy with the one you were given: compound, batch, results and dates.

    HPLC purity vs net peptide content

    This is the most common point of confusion. Lyophilised peptides are not 100% peptide by weight. Alongside the peptide, the powder contains bound water and counter-ions left over from synthesis and purification, such as trifluoroacetate (TFA) or acetate. These are largely invisible to the UV detector, so they do not lower the HPLC purity figure.

    Net peptide content is the share of the total powder weight that is actually peptide. It is measured by other methods, such as amino acid analysis or elemental (nitrogen) analysis, and for many synthetic peptides it is well below 100%. A COA that reports both figures gives a fuller picture. When a report shows only HPLC purity, read it as "how clean is the peptide that is there", not "how much peptide is there". The quantity result in section 6, where offered, is the better guide to content.

    Red flags on a COA

    • No lab name, or a lab that cannot be found independently.
    • No batch or lot number, or the same report used for every batch.
    • Purity shown without a chromatogram, or a chromatogram with no axis labels or integration table.
    • Purity reported but no identity test (no mass spectrometry result).
    • Round, identical results across many different compounds, which can suggest a template rather than real measurements.
    • The same image or file used for two different compounds.
    • Dates that are years old, or a report dated before the batch was made.
    • A report that cannot be found when checked with the lab's own verification tool.

    Printable checklist: 10 things to check on any peptide COA

    Copy or print this list and work through it for each report.

    1. The testing lab is named and can be found independently.
    2. The report has a unique report or task number.
    3. Sample received and test dates are shown and are recent.
    4. The compound name matches the vial label.
    5. The batch or lot number matches the vial label.
    6. Mass spectrometry is reported, and the observed mass matches the expected mass.
    7. HPLC purity is reported with the chromatogram it came from.
    8. A quantity (mg per vial) result is shown, or you know it was not tested.
    9. Any extra tests you need (for example endotoxin) are listed, not assumed.
    10. The report verifies on the lab's own website or with the lab directly.

    Feel free to share or link to this checklist. If you run a resource page, vendor directory or testing database and would like to reference it, the stable URL is this page.

    How Optic Labs approaches COAs

    We publish third-party HPLC results for our core range in the Optic Labs COA library. If anything in a report is unclear, contact us. Our guide to choosing a peptide supplier in Australia covers the other checks worth making, and the peptide storage guide explains how to keep a tested vial in the condition it was tested in.

    Browse the full range of research peptides in Australia, including BPC-157, Retatrutide and BAC water.

    Frequently asked questions

    What does COA stand for?

    COA stands for certificate of analysis. It is a laboratory report that records the test results for a specific batch of a product, such as its purity, identity and quantity.

    What is a good HPLC purity for a research peptide?

    Research-grade peptides are commonly supplied at 98–99% HPLC purity or higher. The figure should come with a chromatogram, and it describes how much of the detectable material is the target peptide, not the total peptide weight in the vial.

    What is the difference between HPLC and mass spectrometry on a COA?

    HPLC measures purity, meaning how much of the sample is one component. Mass spectrometry measures identity, meaning whether that component has the right molecular mass for the compound on the label. A complete COA reports both.

    Why is net peptide content lower than HPLC purity?

    Net peptide content is lower because lyophilised powder also contains water and counter-ions such as TFA or acetate. These add weight but are not counted by the HPLC detector, so a peptide can be 99% pure by HPLC while the powder is well under 100% peptide by weight.

    How do I verify a Janoshik COA?

    Enter the task number from the top of the report and the unique key from its footer on Janoshik's verification page, then compare the stored report with your copy field by field. If the codes do not return a match, the report cannot be confirmed.

    Does a COA prove a peptide is sterile?

    No. HPLC and mass spectrometry do not test for sterility or endotoxin. Those are separate tests, and a COA only covers them if they are listed in the results.

    This article is for educational and research purposes only. Optic Labs products are intended for laboratory research use only and are not for human consumption. Nothing in this article is medical advice or a recommendation to use any compound.